Holowway Pan Hollow Fiber Ultrafiltration Membrane for Wastewater Treatment Filtration

Contact Supplier

Product Highlights

  • High Efficiency Filtration: Removes E. coli >6log and viruses >4log with turbidity <0.1NTU.
  • Advanced NIPS Process: Manufactured using NIPS wet process for superior membrane structure.
  • Robust Housing Material: Housing made of UPVC or ABS with epoxy resin sealing.
  • Wide pH Range: Operates effectively within a pH range of 2 to 13.
  • Effective Backwash System: Enables easy removal of foulants via backwash or chemical cleaning.
  • High Capacity Output: Water output capacity ranges from 1000 to 3000 liters per hour.
  • Low Fouling Design: Inside-out filtration prevents foulants from contacting outer membrane surface.
  • Compact Dimensions: Size is 200mm diameter by 995mm length, weighing 25KG.

Product Images of Holowway Pan Hollow Fiber Ultrafiltration Membrane for Wastewater Treatment Filtration

Holowway Pan Hollow Fiber Ultrafiltration Membrane for Wastewater Treatment Filtration
Holowway Pan Hollow Fiber Ultrafiltration Membrane for Wastewater Treatment Filtration pictures & photos
Holowway Pan Hollow Fiber Ultrafiltration Membrane for Wastewater Treatment Filtration
  • Holowway Pan Hollow Fiber Ultrafiltration Membrane for Wastewater Treatment Filtration
  • Holowway Pan Hollow Fiber Ultrafiltration Membrane for Wastewater Treatment Filtration
    Holowway Pan Hollow Fiber Ultrafiltration Membrane for Wastewater Treatment Filtration

Find Similar Products

Product Description

Product Description
Film detail
Type Hollow fiber
Film making process NIPS(wet process)
Membrane material PAN
nominal bore 0.001-0.02um
Membrane inner/outer diameter 1.0/1.6mm
Component specifications
Housing material UPVC,ABS
Pouring materials Epoxy resin/Polyurethane
End cap materials UPVC,ABS
Connection port standard DN50
Specification 8″
Size(mm) Φ200×995
Effective membrane area 25m2
Transport weight 25KG
Package size 156X32X32CM

Product Name: Outside in Hollow Fiber membrane 200 PAN UF membrane at the Industrial Wastewater Purification Plant

Detailed Photos
Holowway Pan Hollow Fiber Ultrafiltration Membrane for Wastewater Treatment Filtration
Size A B C L1 L2 Quick fitting
Model   (mm) (mm) (mm) (mm) (mm)
HWUF-200   302 Φ237 183.5 995 1415 DN50
Holowway Pan Hollow Fiber Ultrafiltration Membrane for Wastewater Treatment FiltrationHolowway Pan Hollow Fiber Ultrafiltration Membrane for Wastewater Treatment FiltrationHolowway Pan Hollow Fiber Ultrafiltration Membrane for Wastewater Treatment Filtration

Holowway Pan Hollow Fiber Ultrafiltration Membrane for Wastewater Treatment FiltrationHolowway Pan Hollow Fiber Ultrafiltration Membrane for Wastewater Treatment FiltrationHolowway Pan Hollow Fiber Ultrafiltration Membrane for Wastewater Treatment Filtration

Holowway Pan Hollow Fiber Ultrafiltration Membrane for Wastewater Treatment Filtration

Product Parameters
Pre-filter 50-150um
Operation mode Internal pressure operation
molecular cut off 100000 Daltons
Operation pressure 0.02~0.2MPa
Max inlet pressure 0.3MPa
Continuous operation pH range 3~9
Max operating temperature 40ºC
Influent turbidity ≤20NTU
Backwash frequency 15-60min/time
Backwash pressure ≤0.2MPa
Backwash flow rate 100~250L/H.m²
Component Designed flux 40~120L/m²/H
Component Designed water output  200-400LPH
Turbidity of produced water <0.1NTU 
Water pollution density index (SDI15) <3
Removing Escherichia coli >6log  
Removing Virus >4log  
Company Profile

Holowway Pan Hollow Fiber Ultrafiltration Membrane for Wastewater Treatment Filtration

Our Advantages
Hollow fiber UF (ultra filtration) series with inside-out type filtration makes it easy to remove substances filtered out by ultra filtration membrane through backwash or chemical cleaning meanwhile ensures foulants from feed water won't contact with outer surface of ultra filtration membranes preventing foulants from precipitating and stacking onto membrane surface.Housing of UF membrane is made of fiber glass or PVC material,two ends of membrane housing are cast and sealed with epoxy resin.

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASI244797". Items marked "verified" are certified.

Watch Video
Watch Video
HIKINS (JIANGSU) ENVIROTECH CO., LTD
HIKINS (JIANGSU) ENVIROTECH CO., LTD
HIKINS (JIANGSU) ENVIROTECH CO., LTD
HIKINS (JIANGSU) ENVIROTECH CO., LTD
HIKINS (JIANGSU) ENVIROTECH CO., LTD
HIKINS (JIANGSU) ENVIROTECH CO., LTD
HIKINS (JIANGSU) ENVIROTECH CO., LTD
HIKINS (JIANGSU) ENVIROTECH CO., LTD

About Our Factory & Business Background

Address
Small and Medium Enterprise Park, Jiangdu Economic Development Zone, Yangzhou City, Yangzhou, Jiangsu, China
Terms of Payment
LC, T/T, PayPal, Western Union
International Commercial Terms(Incoterms)
FOB, EXW, CFR, CIF, DAT, FAS, DDP, DAP, CIP, CPT, Others, FCA
Average Lead Time
Peak Season Lead Time: 1-3 months
Off Season Lead Time: one month
Nearest Port
Shenzhen, China, Shanghai, China, Guangzhou, China

Our Production Capability & Technical Expertise

Main Products
RO Water Purifier, Vacuum Cleaner, RO Membrane, RO Pump, Robot Vacuum Cleaner, Water Treatment Parts, Water Filter, RO Plant, RO Parts, RO Tank

Our Industry Experience & Global Business Record

Export Year
2011-05-06
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the membrane material used?
The membrane material is PAN (Polyacrylonitrile) with a nominal bore of 0.001-0.02um.
What is the effective membrane area?
The effective membrane area is 25 square meters.
What is the operating pressure range?
The operation pressure ranges from 0.02 to 0.2MPa, with a max inlet pressure of 0.3MPa.
What is the maximum operating temperature?
The maximum operating temperature is 40 degrees Celsius.
How is the membrane cleaned?
Foulants can be removed through backwash or chemical cleaning due to the inside-out filtration design.
What is the backwash frequency?
The backwash frequency is set between 15 to 60 minutes per time.
What is the water output capacity?
The designed water output is 200-400 liters per hour per component.
What is the lead time for production?
Lead time is one month during off-peak season and 1-3 months during peak season.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now