• Hikins Industrial in-Line Purifier Filter Element for Borehole Water Filtration
  • Hikins Industrial in-Line Purifier Filter Element for Borehole Water Filtration
  • Hikins Industrial in-Line Purifier Filter Element for Borehole Water Filtration
  • Hikins Industrial in-Line Purifier Filter Element for Borehole Water Filtration
  • Hikins Industrial in-Line Purifier Filter Element for Borehole Water Filtration
  • Hikins Industrial in-Line Purifier Filter Element for Borehole Water Filtration

Hikins Industrial in-Line Purifier Filter Element for Borehole Water Filtration

Membrane Type: Tubular
Type: RO
Flow Capacity: 7300gpd
Suitable Feed Water Type: TDS Below 20000ppm, Underground Well Water
Active Surface Area: 320FT (29.8 Square Meter)
Stable Salt Rejection: 98.5%
Samples:
US$ 462/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Rating: 5.0/5
Guangdong, China
to see all verified strength labels (28)
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • You May Like
  • Company Profile
  • Certifications
  • Exhibition Show
  • FAQ
Overview

Basic Info.

Model NO.
FRHS-8400
Filtration Preciseness
0.0001micron
Operate Pressure
450psi (3.0MPa)
Material
Polyamide
Weight
13 Kg
Warranty
1 Year
Keyword
Filter Element of Water Purifier
Transport Package
Carton/Wooden Case
Specification
8*40inch(200x200x1100mm)
Trademark
Hikins
Origin
China
HS Code
8421999090
Production Capacity
800/Day

Product Description

Hikins Industrial in-Line Purifier Filter Element for Borehole Water Filtration

Hikins Industrial in-Line Purifier Filter Element for Borehole Water Filtration
Product Description

Hikins FRHS Brackish water membrane elements adopt the most advanced polyamide sheets, it combines the features of low pressure operation, high treated water output, high salt rejection ratio etc.
It is suitable for feed water TDS below 20000ppm, It is mainly used for underground well water, borehole water, tap water filtration desalination purpose, 8" RO membrane is specially applied for small scale chemical industry, pharmaceutical industry, food and electric industry, lab water industry, it's good for school and residential water station drinking water supply.

Features of FRHS-4040
1. Stable salt rejection of 98.5% , minimum salt rejection at 98%
2. Stable permeate water output
3. 8" x 40" international standard size
4. Fit to universal FRP and SS304/316 membrane housing
5. Optional wet membrane upon request

Detailed Photos

Hikins Industrial in-Line Purifier Filter Element for Borehole Water FiltrationHikins Industrial in-Line Purifier Filter Element for Borehole Water FiltrationHikins Industrial in-Line Purifier Filter Element for Borehole Water Filtration
Hikins Industrial in-Line Purifier Filter Element for Borehole Water FiltrationHikins Industrial in-Line Purifier Filter Element for Borehole Water Filtration

Product Parameters
Model NO.
FRHS-8400
Film's effective area
320Ft²(29.8 square meter)
Average permeate flow 
7300GPD
Stable desalination rate
98.5%
Recovery rate
15%
Filtration preciseness
0.0001Micron
Suitable feed water type
TDS below 20000ppm
Underground well water
Film material
Polymiade
Dimension
1016x200x200mm
Weight
13Kgs (Dry)
Packing dimension
230x235x1145mm (1pcs)
Packing weight
14kgs 
 
You May Like
 
Hikins Industrial in-Line Purifier Filter Element for Borehole Water Filtration
Hikins Industrial in-Line Purifier Filter Element for Borehole Water Filtration
 
Company Profile

Guangdong Haiqingxin Environmental Technology Co.,Ltd is the top OEM/ODM Manufacturer for robot vacuum cleaner in South China, as well as the robot cleaner components manufactuer, its business field involves smart homes including robot cleaner, RO water purifier, domestic RO membrane, RO boost pump and water tank, POM fittings and Filter cartridges.

Hikins has become a industry leader in supplying the household facilities in robot cleaners,
RO Water Purifierindustrial and domestic RO products.

Our factory covers an area of 36,000 square meters and has mature injection molding, mold processing, SMT chip processing, productionline assembly, and specialized Industry's supporting service team, R & D and production teams have served OEM / ODM products in nearly 40 countries, Production and management experience of famous brand service.

Hikins has done lots of effort and investment in Robot vacuuming cleaner and Air purifier manufacturing, we are aiming to be your valuable China manufacturing partner and we are looking for distributor and agent worldwide.


Hikins Industrial in-Line Purifier Filter Element for Borehole Water FiltrationHikins Industrial in-Line Purifier Filter Element for Borehole Water Filtration

Certifications

Hikins Industrial in-Line Purifier Filter Element for Borehole Water Filtration

Exhibition Show

Hikins Industrial in-Line Purifier Filter Element for Borehole Water Filtration

FAQ

FAQs on Reverse Osmosis RO membrane OEM manufacturing


Q1: What type of RO membrane is avaliable in your company?
A1: In general, Hikins has Domestic RO membrane and Industrial RO membrane, For Domestic RO membrane, Hikins has Municipal Tap water RO membrane, Rural Area Under Ground water RO membrane, High-flow Low pressure RO membrane, and Brackish water RO membrane.
For Industrial RO membrane, Hikins has Low Pressure Engergy saving RO membrane, BW Brackish water desalination RO membrane, FR Fouling Resistant RO membrane, as well as XLE Extreme Low Pressure RO membrane, and High Salinity Brackish Water Desalination RO membrane.

Q2: What is Salt Rejection Ratio?
A2: The Salt rejection describes the quality of salt removed from the Reverse Osmosis feed water stream as a percentage. It's one of the key element of the RO membrane quality, however, other essential elements such as RO membrane performance durability,stability, application scope in different region, and permeate flow output at the same pressure will all be the important factors to judge the quality of the membrane.

Q3: Is the Salt reation of the RO membrane the higher the better?
A3: This will be depending on the feed water quality, if the feed water quality is good, even a 90% salt rejection membrane will be workable, if the feed water is with bad quality and with brackish water environment, a higher salt rejection above 95% is an ideal choice. For any membrane that meet the local drinking water standard will be a good membrane.

Q4: Is there are any other element we need to take into consideration when selection the RO membrane?
A4: Yes, the pre-treatment filter cartridge and pre-treatment system will affect the RO membrane performance as well, please select good quality filters and pre-treatment system.

Q5: Why there are white foam-like water being in the treated water at the initial usage?
A5: To preserve the RO membrane for a long shelf-life, and prevent the membrane from being oxydized, a water soluble protection material is coated on the surface of the membrane, which will be rejected in both the rejected water and treated water, for initial use, both rejected water and treated water should be rejected and the the RO membrane should be thourghly cleansed. The treated water at initial use shall not be injected to the water storage tank.

Q6: Why there are bublles in the treated water?
A6: Oxygen and Nitrogensand carbon dioxide is water soluble in the molecular form, during the water filtration process in the Reverse Osmosis process, those air will be released due to the pressure change between input water and output water. Those air is not harmful, just like Coca-cola.

Q7: Why dry RO membrane has a salt rejection rising process from its initial usage?
A7: The performance of the RO membrane is strictly conencted to the wetness of the membrane, when the membrane is wet, it will reach to ts maximum performance, dry membrane has a process to become wet from its initial usage. Make sure that the membrane hsould be rinsed after each usage.

Q8: Why Active carbon filter is requested for RO membrane?
A8: Chloride and chlorine content is harmful from the feed water, RO membrane is easily to be damaged as the surface of the RO membrane will be easily being oxydized.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2018

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company
Registered Capital
15000000 USD
Plant Area
>2000 square meters