Hikins Brand 150psi Low Pressure RO Membrane Lp-4040 for 2000ppm Source Water

Product Details
Customization: Available
Membrane Type: Tubular
Type: RO
Still deciding? Get samples of US$ 52/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Patents Awarded
The supplier had awarded 2 patents, you can check the Audit Report for more information
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
100% Finished Products Inspection
The supplier inspects 100% of finished products.
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (28)
  • Hikins Brand 150psi Low Pressure RO Membrane Lp-4040 for 2000ppm Source Water
  • Hikins Brand 150psi Low Pressure RO Membrane Lp-4040 for 2000ppm Source Water
  • Hikins Brand 150psi Low Pressure RO Membrane Lp-4040 for 2000ppm Source Water
  • Hikins Brand 150psi Low Pressure RO Membrane Lp-4040 for 2000ppm Source Water
  • Hikins Brand 150psi Low Pressure RO Membrane Lp-4040 for 2000ppm Source Water
  • Hikins Brand 150psi Low Pressure RO Membrane Lp-4040 for 2000ppm Source Water
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • You May Like
  • Company Profile
  • Certifications
  • Exhibition Show
  • FAQ
Overview

Basic Info.

Model NO.
LP-4040
Flow Capacity
2200 Gpd
Suitable Feed Water Type
TDS Below 2000ppm, Underground Well Water
Active Surface Area
78FT (7.5 Square Meter)
Stable Salt Rejection
99.5%
Filtration Preciseness
0.0001micron
Feature 1
Energy Saving
Material
Polyamide
Weight
2.9 Kg
Warranty
1 Year
Keyword
RO Membrane Sheet
Application
Industrial Reverse Osmosis, Water Treatment
Transport Package
Carton/Wooden Case
Specification
4" x 40" (130x125x1100mm)
Trademark
Hikins
Origin
China
HS Code
8421999090
Production Capacity
760/Day

Packaging & Delivery

Package Size
110.00cm * 13.00cm * 13.00cm
Package Gross Weight
3.500kg

Product Description

HIKINS brand 150PSI Low pressure RO Membrane LP-4040 for 2000PPM source water
Hikins Brand 150psi Low Pressure RO Membrane Lp-4040 for 2000ppm Source Water
Product Description
LP(Low Pressure) series of reverse osmosis membrane elements for brackish water desalination, using the world's most advanced brackish water professional polyamide composite reverse osmosis membrane sheet carefully rolled, can desalinate brackish water, surface water, groundwater and other water sources with salt content below 5000mg.
It's specially applied for small scale chemical industry, pharmaceutical industry, food and electric industry, lab water industry, it's good for school and residential water station drinking water supply.
 
Features of LP series

1. High desalination rate, large flow rate, operating pressure is more than 30% lower than ordinary brackish water membrane, which can
    significantly reduce the energy consumption of system operation, reduce the system requirements for pumps, pressure vessels, pipelines
    and other components, saving investment and operating costs.

 
2. High stability, optimized membrane element structure, using a wide flow channel short membrane page design, the series of membrane
    elements with high operational stability and cleanable performance.

 
3. Wide selection and complete series of specifications, with diameters of 2.5, 4.0 and 8.0 inches and lengths of 14, 21 and 40 inches, which
    can meet the needs of systems with different water production volumes, and can also produce membrane elements of various sizes and
    specifications according to customer needs.
 
Features of LP-4040

1. Advanced membrane technology with innovative thin layer composite membrane design. Low energy consumption in operation.
2. Provides stable, high rejection of contaminates even with high TDS water sources. Stable salt rejection of 99.5%.
3. Stable permeate water output, less fouling requiring less frequent cleaning and changeouts.
4. 4" x 40" international standard size,fit to universal FRP and SS304/316 membrane housing.
5. 100% dry-stored membrane maximizing shelf life. Optional wet membrane upon request.
 
Detailed Photos

Hikins Brand 150psi Low Pressure RO Membrane Lp-4040 for 2000ppm Source Water
Hikins Brand 150psi Low Pressure RO Membrane Lp-4040 for 2000ppm Source Water




Hikins Brand 150psi Low Pressure RO Membrane Lp-4040 for 2000ppm Source WaterHikins Brand 150psi Low Pressure RO Membrane Lp-4040 for 2000ppm Source Water

Product Parameters
  
Model
LP-4040
Film's effective area
78Ft²(7.5 square meter)
Average permeate flow 
2200GPD 
Stable desalination rate
99.5%
Recovery rate
15%
Filtration preciseness
0.0001Micron
Suitable feed water type
TDS below 2000ppm, Underground well water
Film material
Polymiade
Dimension
4" x 40" (130x125x1100mm)
Weight
2.3Kgs (Dry)
Packing dimension
130x130x1100mm (1pcs)
Packing weight
2.9kgs 

Hikins Brand 150psi Low Pressure RO Membrane Lp-4040 for 2000ppm Source Water
You May Like
 
Hikins Brand 150psi Low Pressure RO Membrane Lp-4040 for 2000ppm Source Water
Hikins Brand 150psi Low Pressure RO Membrane Lp-4040 for 2000ppm Source Water
 
Company Profile

Guangdong Haiqingxin Environmental Technology Co.,Ltd is the top OEM/ODM Manufacturer for robot vacuum cleaner in South China, as well as the robot cleaner components manufactuer, its business field involves smart homes including robot cleaner, RO water purifier, domestic RO membrane, RO boost pump and water tank, POM fittings and Filter cartridges.

Hikins has become a industry leader in supplying the household facilities in robot cleaners,
RO Water Purifierindustrial and domestic RO products.

Our factory covers an area of 36,000 square meters and has mature injection molding, mold processing, SMT chip processing, productionline assembly, and specialized Industry's supporting service team, R & D and production teams have served OEM / ODM products in nearly 40 countries, Production and management experience of famous brand service.

Hikins has done lots of effort and investment in Robot vacuuming cleaner and Air purifier manufacturing, we are aiming to be your valuable China manufacturing partner and we are looking for distributor and agent worldwide.


Hikins Brand 150psi Low Pressure RO Membrane Lp-4040 for 2000ppm Source WaterHikins Brand 150psi Low Pressure RO Membrane Lp-4040 for 2000ppm Source Water

Certifications

Hikins Brand 150psi Low Pressure RO Membrane Lp-4040 for 2000ppm Source Water

Exhibition Show

Hikins Brand 150psi Low Pressure RO Membrane Lp-4040 for 2000ppm Source Water

FAQ

FAQs on Reverse Osmosis RO membrane OEM manufacturing


Q1: What type of RO membrane is avaliable in your company?
A1: In general, Hikins has Domestic RO membrane and Industrial RO membrane, For Domestic RO membrane, Hikins has Municipal Tap water RO membrane, Rural Area Under Ground water RO membrane, High-flow Low pressure RO membrane, and Brackish water RO membrane.
For Industrial RO membrane, Hikins has Low Pressure Engergy saving RO membrane, BW Brackish water desalination RO membrane, FR Fouling Resistant RO membrane, as well as XLE Extreme Low Pressure RO membrane, and High Salinity Brackish Water Desalination RO membrane.

Q2: What is Salt Rejection Ratio?
A2: The Salt rejection describes the quality of salt removed from the Reverse Osmosis feed water stream as a percentage. It's one of the key element of the RO membrane quality, however, other essential elements such as RO membrane performance durability,stability, application scope in different region, and permeate flow output at the same pressure will all be the important factors to judge the quality of the membrane.

Q3: Is the Salt reation of the RO membrane the higher the better?
A3: This will be depending on the feed water quality, if the feed water quality is good, even a 90% salt rejection membrane will be workable, if the feed water is with bad quality and with brackish water environment, a higher salt rejection above 95% is an ideal choice. For any membrane that meet the local drinking water standard will be a good membrane.

Q4: Is there are any other element we need to take into consideration when selection the RO membrane?
A4: Yes, the pre-treatment filter cartridge and pre-treatment system will affect the RO membrane performance as well, please select good quality filters and pre-treatment system.

Q5: Why there are white foam-like water being in the treated water at the initial usage?
A5: To preserve the RO membrane for a long shelf-life, and prevent the membrane from being oxydized, a water soluble protection material is coated on the surface of the membrane, which will be rejected in both the rejected water and treated water, for initial use, both rejected water and treated water should be rejected and the the RO membrane should be thourghly cleansed. The treated water at initial use shall not be injected to the water storage tank.

Q6: Why there are bublles in the treated water?
A6: Oxygen and Nitrogensand carbon dioxide is water soluble in the molecular form, during the water filtration process in the Reverse Osmosis process, those air will be released due to the pressure change between input water and output water. Those air is not harmful, just like Coca-cola.

Q7: Why dry RO membrane has a salt rejection rising process from its initial usage?
A7: The performance of the RO membrane is strictly conencted to the wetness of the membrane, when the membrane is wet, it will reach to ts maximum performance, dry membrane has a process to become wet from its initial usage. Make sure that the membrane hsould be rinsed after each usage.

Q8: Why Active carbon filter is requested for RO membrane?
A8: Chloride and chlorine content is harmful from the feed water, RO membrane is easily to be damaged as the surface of the RO membrane will be easily being oxydized.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier