High Slat Rejection Sw8040 8 Inch Membrane Element RO Water System

Product Details
Customization: Available
Membrane Type: Spiral
Type: RO
Still deciding? Get samples of US$ 452/Piece
Request Sample
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Patents Awarded
The supplier had awarded 2 patents, you can check the Audit Report for more information
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
100% Finished Products Inspection
The supplier inspects 100% of finished products.
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (28)
  • High Slat Rejection Sw8040 8 Inch Membrane Element RO Water System
  • High Slat Rejection Sw8040 8 Inch Membrane Element RO Water System
  • High Slat Rejection Sw8040 8 Inch Membrane Element RO Water System
  • High Slat Rejection Sw8040 8 Inch Membrane Element RO Water System
  • High Slat Rejection Sw8040 8 Inch Membrane Element RO Water System
  • High Slat Rejection Sw8040 8 Inch Membrane Element RO Water System
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Packaging & Shipping
  • Company Profile
  • Our Advantages
  • FAQ
Overview

Basic Info.

Model NO.
SW-8040
Suitable Feed Water Type
TDS Below 40000ppm of Water Source
Active Surface Area
380FT (35.2 Square Meter)
Stable Salt Rejection
99.5%
Filtration Preciseness
0.0001micron
Feature
High TDS Applicative
Material
Composite Polyamide
Weight
11.5 Kg
Warranty
1 Year
Keyword
RO Seawater 8040 Membranes
Transport Package
1PCS/CTN
Specification
8" x 40"(1015mmx200.2mmx200.2mm)
Trademark
HIKINS
Origin
Dongguan, China
HS Code
8421991000
Production Capacity
1500PCS/Day

Product Description

Product Description

Product Name: high slat rejection SW8040 8 inch membrane element  ro water system 
Model: SW3-8040  
Working Pressure: 800PSI
Working Flow: 6000GPD
Salt rejection rate: 99.5%
Testing Temperature: 25 degree centigrade

High Slat Rejection Sw8040 8 Inch Membrane Element RO Water System


High Slat Rejection Sw8040 8 Inch Membrane Element RO Water System
Unit: mm

Model A B C
8040 1015±1 200.2±0.2 29±0.2
Detailed Photos

High Slat Rejection Sw8040 8 Inch Membrane Element RO Water System
High Slat Rejection Sw8040 8 Inch Membrane Element RO Water System
High Slat Rejection Sw8040 8 Inch Membrane Element RO Water System

Product Parameters
Series Model Active area Salt rejection Water output Test prssure
Ft2(m2) % GPD(m3/d) PSI (Mpa)

XLE
(ULP)
500ppm
XLE-2521 13(1.2) 99 500(1.9) 100(0.69)
XLE-2540 28(2.6) 99 1100(4.2) 100(0.69)
XLE-3020 24(2.2) 99 550(2.1) 100(0.69)
XLE-4021 36(3.3) 99 1300(4.9) 100(0.69)
XLE-4040 88(8.2) 99.2 2600(9.8) 100(0.69)
XLE-8365 365(34) 99.2 11000(41) 100(0.69)
XLE-8400 400(37) 99.2 12000(45) 100(0.69)
XLE-8440 440(41) 99.2 13000(49) 100(0.69)

LP
2000ppm
LP-2521 13(1.2) 99 370(1.4) 150(1.05)
LP-2540 28(2.6) 99 800(3.0) 150(1.05)
LP-3020 24(2.2) 99 420(1.6) 150(1.05)
LP-4021 36(3.3) 99 1000(3.8) 150(1.05)
LP-4040 88(8.2) 99.5 2400(9.1) 150(1.05)
LP-8365 365(34) 99.5 10000(38) 150(1.05)
LP-8400 400(37) 99.5 11000(41) 150(1.05)
LP-8440 440(41) 99.5 12000(45) 150(1.05)

BW
5000ppm
BW-2521 13(1.2) 99.3 350(1.3) 225(1.55)
BW-2540 28(2.6) 99.3 750(2.8) 225(1.55)
BW-3020 26(2.4) 99.3 600(2.4) 225(1.55)
BW-4021 36(3.3) 99.3 900(3.4) 225(1.55)
BW-4040 88(8.2) 99.5 2400(9.1) 225(1.55)
BW-8365 365(34) 99.5 10000(38) 225(1.55)
BW-8400 400(37) 99.5 11000(41) 225(1.55)
BW-8440 440(41) 99.5 12000(45) 225(1.55)
BW-FR
5000ppm
BW-4040FR 85(7.9) 99.5 2400(9.0) 225(1.55)
BW-8365FR 365(34) 99.5 9600(36.3) 225(1.55)
BW-8400FR 400(37.2) 99.5 10500(39.7) 225(1.55)
FRHS
20000ppm
FRHS-4040 75(7.0) 98.5 1800(6.8) 450(3.0)
FRHS-8400 320(29.8) 98.5 7300(27.6) 450(3.0)

High Slat Rejection Sw8040 8 Inch Membrane Element RO Water System
High Slat Rejection Sw8040 8 Inch Membrane Element RO Water System

Packaging & Shipping

High Slat Rejection Sw8040 8 Inch Membrane Element RO Water System

Model Carton size Carton Weight Unit Weight Total Weight
(mm) (kg) (kg) (kg/CTN)
8040 1145*230*235 1.2 Dry:11.5 12.7
Weight:13.6 14.8
4040 1100*130*125 0.6 Dry:2.3 2.9
Weight:3 3.6
4021 575*120*120 0.23 Dry:1.3 1.53
2540 1060*80*80 0.25 Dry:1 1.25
2521 580*85*85 0.15 0.53 0.7
3020 575*120*120 0.23 0.8 1.03
Company Profile

High Slat Rejection Sw8040 8 Inch Membrane Element RO Water System
High Slat Rejection Sw8040 8 Inch Membrane Element RO Water System
High Slat Rejection Sw8040 8 Inch Membrane Element RO Water System

Our Advantages

A.  Self produced membrane sheet.
B.  Quality strictly controlled by QC from Raw material, finished products.
C.  Fast delivery time, and competitive prices.
D.  Full range of RO membrane, 3020, 2521, 2540, 4021, 4040, 8040(8356, 8400, 8440).

FAQ

FAQs on Reverse Osmosis RO membrane OEM manufacturing
 

Q1: What type of RO membrane is avaliable in your company?

A1: In general, Hikins has Domestic RO membrane and Industrial RO membrane, For Domestic RO membrane, Hikins has Municipal Tap water RO membrane, Rural Area Under Ground water RO membrane, High-flow Low pressure RO membrane, and Brackish water RO membrane. For Industrial RO membrane, Hikins has Low Pressure Engergy saving RO membrane, BW Brackish water desalination RO membrane, FR Fouling Resistant RO membrane, as well as XLE Extreme Low Pressure RO membrane, and High Salinity Brackish Water Desalination RO membrane.

 

Q2: What is Salt Rejection Ratio?

A2: The Salt rejection describes the quality of salt removed from the Reverse Osmosis feed water stream as a percentage. It's one of the key element of the RO membrane quality, however, other essential elements such as RO membrane performance durability, stability, application scope in different region, and permeate flow output at the same pressure will all be the important factors to judge the quality of the membrane.

 

Q3: Is the Salt reation of the RO membrane the higher the better?

A3: This will be depending on the feed water quality, if the feed water quality is good, even a 90% salt rejection membrane will be workable, if the feed water is with bad quality and with brackish water environment, a higher salt rejection above 95% is an ideal choice. For any membrane that meet the local drinking water standard will be a good membrane.

 

Q4: Is there are any other element we need to take into consideration when selection the RO membrane?

A4: Yes, the pre-treatment filter cartridge and pre-treatment system will affect the RO membrane performance as well, please select good quality filters and pre-treatment system.

 

Q5: Why there are white foam-like water being in the treated water at the initial usage?

A5: To preserve the RO membrane for a long shelf-life, and prevent the membrane from being oxydized, a water soluble protection material is coated on the surface of the membrane, which will be rejected in both the rejected water and treated water, for initial use, both rejected water and treated water should be rejected and the the RO membrane should be thourghly cleansed. The treated water at initial use shall not be injected to the water storage tank.

 

Q6: Why there are bublles in the treated water?

A6: Oxygen and Nitrogensand carbon dioxide is water soluble in the molecular form, during the water filtration process in the Reverse Osmosis process, those air will be released due to the pressure change between input water and output water. Those air is not harmful, just like Coca-cola.

 

Q7: Why dry RO membrane has a salt rejection rising process from its initial usage?

A7: The performance of the RO membrane is strictly conencted to the wetness of the membrane, when the membrane is wet, it will reach to ts maximum performance, dry membrane has a process to become wet from its initial usage. Make sure that the membrane hsould be rinsed after each usage.

 

Q8: Why Active carbon filter is requested for RO membrane?

A8: Chloride and chlorine content is harmful from the feed water, RO membrane is easily to be damaged as the surface of the RO membrane will be easily being oxydized.

Send your message to this supplier