150psi 8040 Size 10000gpd 11000g 12000 Gpd and 4040 Industrial RO Membrane Manufacturer

Membrane Type: Spiral
Type: RO
8400 Capacity: 11000gpd
Samples:
US$ 200/Piece 1 Piece(Min.Order)
| Order Sample
Outer box size 1145*230*235mm
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
150psi 8040 Size 10000gpd 11000g 12000 Gpd and 4040 Industrial RO Membrane Manufacturer pictures & photos
150psi 8040 Size 10000gpd 11000g 12000 Gpd and 4040 Industrial RO Membrane Manufacturer
US $159.8-173.7 / Piece
Min. Order: 50 Pieces
Diamond Member Since 2018

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory, Trading Company
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Packaging & Shipping
  • Company Profile
  • Our Advantages
  • FAQ
Overview

Basic Info.

Model NO.
LP-8040 XYM
TDS
2000ppm
Effective Film Area
13-440FT2
Working Water Pressure
150psi
Salt Rejection
99.5%
Transport Package
1PCS/CTN
Specification
8400
Trademark
XYM
Origin
Dongguan, China
HS Code
8421991000
Production Capacity
1500PCS/Day

Packaging & Delivery

Package Size
114.50cm * 23.00cm * 23.50cm
Package Gross Weight
12.700kg
Lead Time
15 days (1 - 50 Pieces)
To be negotiated ( > 50 Pieces)

Product Description

Product Description

Product Name: 150psi 8040 Size 10000gpd 11000gpd 12000 Gpd Industrial RO Membrane Manufacturer
Model: LP-8400  
Working Pressure: 150PSI
Working Flow: 11000GPD
Salt rejection rate: 99.3%
Testing Temperature: 25 degree

Model A B C
8040 1015±1 200.2±0.2 29±0.2

150psi 8040 Size 10000gpd 11000g 12000 Gpd and 4040 Industrial RO Membrane Manufacturer

Detailed Photos

150psi 8040 Size 10000gpd 11000g 12000 Gpd and 4040 Industrial RO Membrane Manufacturer150psi 8040 Size 10000gpd 11000g 12000 Gpd and 4040 Industrial RO Membrane Manufacturer150psi 8040 Size 10000gpd 11000g 12000 Gpd and 4040 Industrial RO Membrane Manufacturer

Product Parameters
Series Model Active area Salt rejection Water output Test prssure
Ft2(m2) % GPD(m3/d) PSI (Mpa)

XLE
(ULP)
500ppm
XLE-2521 13(1.2) 99 500(1.9) 100(0.69)
XLE-2540 28(2.6) 99 1100(4.2) 100(0.69)
XLE-3020 24(2.2) 99 550(2.1) 100(0.69)
XLE-4021 36(3.3) 99 1300(4.9) 100(0.69)
XLE-4040 88(8.2) 99.2 2600(9.8) 100(0.69)
XLE-8365 365(34) 99.2 11000(41) 100(0.69)
XLE-8400 400(37) 99.2 12000(45) 100(0.69)
XLE-8440 440(41) 99.2 13000(49) 100(0.69)

LP
2000ppm
LP-2521 13(1.2) 99 370(1.4) 150(1.05)
LP-2540 28(2.6) 99 800(3.0) 150(1.05)
LP-3020 24(2.2) 99 420(1.6) 150(1.05)
LP-4021 36(3.3) 99 1000(3.8) 150(1.05)
LP-4040 88(8.2) 99.5 2400(9.1) 150(1.05)
LP-8365 365(34) 99.5 10000(38) 150(1.05)
LP-8400 400(37) 99.5 11000(41) 150(1.05)
LP-8440 440(41) 99.5 12000(45) 150(1.05)

BW
5000ppm
BW-2521 13(1.2) 99.3 350(1.3) 225(1.55)
BW-2540 28(2.6) 99.3 750(2.8) 225(1.55)
BW-3020 26(2.4) 99.3 600(2.4) 225(1.55)
BW-4021 36(3.3) 99.3 900(3.4) 225(1.55)
BW-4040 88(8.2) 99.5 2400(9.1) 225(1.55)
BW-8365 365(34) 99.5 10000(38) 225(1.55)
BW-8400 400(37) 99.5 11000(41) 225(1.55)
BW-8440 440(41) 99.5 12000(45) 225(1.55)
BW-FR
5000ppm
BW-4040FR 85(7.9) 99.5 2400(9.0) 225(1.55)
BW-8365FR 365(34) 99.5 9600(36.3) 225(1.55)
BW-8400FR 400(37.2) 99.5 10500(39.7) 225(1.55)
FRHS
20000ppm
FRHS-4040 75(7.0) 98.5 1800(6.8) 450(3.0)
FRHS-8400 320(29.8) 98.5 7300(27.6) 450(3.0)

150psi 8040 Size 10000gpd 11000g 12000 Gpd and 4040 Industrial RO Membrane Manufacturer150psi 8040 Size 10000gpd 11000g 12000 Gpd and 4040 Industrial RO Membrane Manufacturer

Packaging & Shipping

150psi 8040 Size 10000gpd 11000g 12000 Gpd and 4040 Industrial RO Membrane Manufacturer

Model Carton size Carton Weight Unit Weight Total Weight
(mm) (kg) (kg) (kg/CTN)
8040 1145*230*235 1.2 Dry:11.5 12.7
Weight:13.6 14.8
4040 1100*130*125 0.6 Dry:2.3 2.9
Weight:3 3.6
4021 575*120*120 0.23 Dry:1.3 1.53
2540 1060*80*80 0.25 Dry:1 1.25
2521 580*85*85 0.15 0.53 0.7
3020 575*120*120 0.23 0.8 1.03
Company Profile

150psi 8040 Size 10000gpd 11000g 12000 Gpd and 4040 Industrial RO Membrane Manufacturer150psi 8040 Size 10000gpd 11000g 12000 Gpd and 4040 Industrial RO Membrane Manufacturer150psi 8040 Size 10000gpd 11000g 12000 Gpd and 4040 Industrial RO Membrane Manufacturer

Our Advantages

A.  Self produced membrane sheet.
B.  Quality strictly controlled by QC from Raw material, finished products.
C.  Fast delivery time, and competitive prices.
D.  Full range of RO membrane, 3020, 2521, 2540, 4021, 4040, 8040(8356, 8400, 8440).

FAQ

FAQs on Reverse Osmosis RO membrane OEM manufacturing

Q1: What type of RO membrane is avaliable in your company?

A1: In general, Hikins has Domestic RO membrane and Industrial RO membrane, For Domestic RO membrane, Hikins has Municipal Tap water RO membrane, Rural Area Under Ground water RO membrane, High-flow Low pressure RO membrane, and Brackish water RO membrane. For Industrial RO membrane, Hikins has Low Pressure Engergy saving RO membrane, BW Brackish water desalination RO membrane, FR Fouling Resistant RO membrane, as well as XLE Extreme Low Pressure RO membrane, and High Salinity Brackish Water Desalination RO membrane.

 

Q2: What is Salt Rejection Ratio?

A2: The Salt rejection describes the quality of salt removed from the Reverse Osmosis feed water stream as a percentage. It's one of the key element of the RO membrane quality, however, other essential elements such as RO membrane performance durability, stability, application scope in different region, and permeate flow output at the same pressure will all be the important factors to judge the quality of the membrane.

 

Q3: Is the Salt reation of the RO membrane the higher the better?

A3: This will be depending on the feed water quality, if the feed water quality is good, even a 90% salt rejection membrane will be workable, if the feed water is with bad quality and with brackish water environment, a higher salt rejection above 95% is an ideal choice. For any membrane that meet the local drinking water standard will be a good membrane.

 

Q4: Is there are any other element we need to take into consideration when selection the RO membrane?

A4: Yes, the pre-treatment filter cartridge and pre-treatment system will affect the RO membrane performance as well, please select good quality filters and pre-treatment system.

 

Q5: Why there are white foam-like water being in the treated water at the initial usage?

A5: To preserve the RO membrane for a long shelf-life, and prevent the membrane from being oxydized, a water soluble protection material is coated on the surface of the membrane, which will be rejected in both the rejected water and treated water, for initial use, both rejected water and treated water should be rejected and the the RO membrane should be thourghly cleansed. The treated water at initial use shall not be injected to the water storage tank.

 

Q6: Why there are bublles in the treated water?

A6: Oxygen and Nitrogensand carbon dioxide is water soluble in the molecular form, during the water filtration process in the Reverse Osmosis process, those air will be released due to the pressure change between input water and output water. Those air is not harmful, just like Coca-cola.

 

Q7: Why dry RO membrane has a salt rejection rising process from its initial usage?

A7: The performance of the RO membrane is strictly conencted to the wetness of the membrane, when the membrane is wet, it will reach to ts maximum performance, dry membrane has a process to become wet from its initial usage. Make sure that the membrane hsould be rinsed after each usage.

 

Q8: Why Active carbon filter is requested for RO membrane?

A8: Chloride and chlorine content is harmful from the feed water, RO membrane is easily to be damaged as the surface of the RO membrane will be easily being oxydized.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
150psi 8040 Size 10000gpd 11000g 12000 Gpd and 4040 Industrial RO Membrane Manufacturer pictures & photos
150psi 8040 Size 10000gpd 11000g 12000 Gpd and 4040 Industrial RO Membrane Manufacturer
US $159.8-173.7 / Piece
Min. Order: 50 Pieces
Diamond Member Since 2018

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory, Trading Company
Registered Capital
15000000 USD
Plant Area