Hikins 100G 2012-100 Membrane Domestic Reverse Osmosis Residential RO Membrane

Product Details
Customization: Available
Material: Plastic
Application: Industry, Food and Beverage, Medicine, Home Drinking Water
Still deciding? Get samples of US$ 6/Piece
Request Sample
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Patents Awarded
The supplier had awarded 2 patents, you can check the Audit Report for more information
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
100% Finished Products Inspection
The supplier inspects 100% of finished products.
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (28)
  • Hikins 100G 2012-100 Membrane Domestic Reverse Osmosis Residential RO Membrane
  • Hikins 100G 2012-100 Membrane Domestic Reverse Osmosis Residential RO Membrane
  • Hikins 100G 2012-100 Membrane Domestic Reverse Osmosis Residential RO Membrane
  • Hikins 100G 2012-100 Membrane Domestic Reverse Osmosis Residential RO Membrane
  • Hikins 100G 2012-100 Membrane Domestic Reverse Osmosis Residential RO Membrane
  • Hikins 100G 2012-100 Membrane Domestic Reverse Osmosis Residential RO Membrane
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Installation Instructions
  • Company Profile
  • Our Advantages
  • FAQ
Overview

Basic Info.

Model NO.
2012-100-13
Filter Connector
Standard
Filtration Grade
0.0001um
Activated Carbon Filter Type
None
Use
Parts of RO Water Purifier
Filtration Precision
0.0001um
Capacity
100GPD
Produced Water
Drinking Water
Desalination Rate
97%
Effective Area
5 Square Foot(0.5 Square Meter)
Working Pressure
65psi
Feature
Low Pressure
Applicable Water Sources
TDS<=500ppm, Tap Water, Municipal Water
Size
238*47*47mm
Key Word
97% Salt Rejection Membrane
Transport Package
25PCS/CTN
Specification
100GPD
Trademark
HIKINS
Origin
Dongguan, China
HS Code
8421991000
Production Capacity
100000PCS/Month

Product Description

Hikins 100G 2012-100 Membrane Domestic Reverse Osmosis Residential RO Membrane
Product Description

Hikins 2012-100-13 household reverse osmosis membrane elements are small composite membranes developed by Hikins for household use


Main Features:
Ultra low pressure, large flux characteristics.
 Can maintain high water flux at very low operating pressure, its operating pressure is only

0.4mpa, can be used for the treatment of household tap water.
 

It is suitable for desalting water from tap water and municipal water sources with salinity below about 500ppm.

Main uses: Household, hospital, laboratory water equipment and other small systems.

Hikins 100G 2012-100 Membrane Domestic Reverse Osmosis Residential RO Membrane

Specification
Model NO. 2012-100 13
Active Area 5Ft2 (0.5m2 )
Removal Rate 97%
Film Body Size 238*47*47mm
Water Rroduction Rate 100GPD
Working Pressure 65PSI
Operating Pressure 0.4MPa
Packing Quantity 25PCS/CTN
Packing Size 320*320*340mm
Gross Weight 7KGS
Detailed Photos

Hikins 100G 2012-100 Membrane Domestic Reverse Osmosis Residential RO Membrane
 

Hikins 100G 2012-100 Membrane Domestic Reverse Osmosis Residential RO MembraneHikins 100G 2012-100 Membrane Domestic Reverse Osmosis Residential RO Membrane

Product Parameters

Hikins 100G 2012-100 Membrane Domestic Reverse Osmosis Residential RO MembraneHikins 100G 2012-100 Membrane Domestic Reverse Osmosis Residential RO Membrane

Series Model Active Area Salt Rejection Water Output Test Prssure
Ft2(m2) % GPD PSI
1510 1510-50 2(0.17) 97 50 65
1510-75 3(0.25) 97 75 65
ECO 1812-50 9L 3.5(0.35) 97 50 65
1812-75 9L 3.5(0.35) 97 75 65
238mm 1812-50 13L 4(0.4) 97 50 65
1812-75 13L 4(0.4) 97 75 65
2012-100 13L 5(0.5) 97 100 65
4000ppm 1812-75 4(0.4) 95 75 120
2012-80 4.5(0.45) 96 80 120
2012-100 5(0.5) 96.5 100 120
Regular
1812/2012
2000ppm
1812-50 11L 4(0.4) 97 50 65
1812-75 11L 4(0.4) 97 75 65
2012-80 12L 4.5(0.45) 97 80 65
2012-100 13L 5(0.5) 97 100 65
2012-125 13L 5.2(0.52) 97 125 65
2012-150 6(0.6) 97 150 65
2012-180 10(1.0) 97 180 65
2012-200 7.5(0.7) 97 200 65
Series Model Active Area Salt Rejection Water Output Test Prssure
Ft2(m2) % GPD PSI
3012 3012-200 8.6(0.8) 97 200 65
3012-250 10.8(1) 97 250 65
3012-300 13(1.2) 97 300 65
3012-400 15(1.4) 97 400 80
3012-600 20.5(1.9) 96 600 90
3013 3013-400 15(1.4) 97 400 80
3013-500 18.3(1.7) 96 500 80
3013-600 20.5(1.9) 96 600 90
3213 3213-600 20.5(1.9) 96 600 90
3213-800 26(2.5) 96 800 90
3413 3413-800 28(26) 96 800 90
3413-1000 32(3) 95 1000 90
Inline RO 1812-75 4(0.4) 97 50/75/100 65

 

Installation Instructions

Hikins 100G 2012-100 Membrane Domestic Reverse Osmosis Residential RO Membrane

Installation Instructions

Hikins 100G 2012-100 Membrane Domestic Reverse Osmosis Residential RO Membrane
Unscrew the nut on the membrane shell cover at the inlet water connection end, take out the inlet water pipe, then use the membrane shell wrench to loose the membrane shell cover. Take the RO membrane from its packaging, put the end of the membrane with 2 O-rings into the RO membrane shell (See The following Diagram ) and push it in, finally screw the membrane shell cover back on, and tighten it with membrane shell wrench, put the inlet water pipe back into the inlet water connector and screw the nut tightly, then push the membrane shell card into the large single clip.



Direction For Use
 

1.When installing the RO membrane, you should pay attention to the direction of the membrane;

2. When installing the RO membrane, you should first make sure that one end of the membrane has 2 O-rings;

3. When installing, be sure to put the end with the O-ring into the end of the membrane shell with the pure water connection, for correct installation you need only a little force to put the RO membrane into the membrane shell, if you encounter too much resistance, please do not force the membrane into the shell, or it could lead to permanent damage to the membrane shell or membrane components (the membrane manufacturer does not take the responsibility for replacing components due to damage made during installation);

4. Damage to the membrane shell and membrane element caused under above mentioned situation is not covered by the warranty.

Company Profile

Hikins 100G 2012-100 Membrane Domestic Reverse Osmosis Residential RO Membrane
Hikins 100G 2012-100 Membrane Domestic Reverse Osmosis Residential RO Membrane
Hikins 100G 2012-100 Membrane Domestic Reverse Osmosis Residential RO Membrane
Hikins 100G 2012-100 Membrane Domestic Reverse Osmosis Residential RO Membrane

Our Advantages

A. Full range RO membranes 50GPD to 1000GPD for home use.
B. Self-produced membrane sheet.
C. Each roll of membrane sheet will be tested before bulk production.
D. Each finished membrane will need pass vacuum testing, to make sure salt rejection rate.
E. OEM and ODM orders are welcomed.

FAQ

FAQs on Reverse Osmosis RO membrane OEM manufacturing
 

Q1: What type of RO membrane is avaliable in your company?

A1: In general, Hikins has Domestic RO membrane and Industrial RO membrane, For Domestic RO membrane, Hikins has Municipal Tap water RO membrane, Rural Area Under Ground water RO membrane, High-flow Low pressure RO membrane, and Brackish water RO membrane. For Industrial RO membrane, Hikins has Low Pressure Engergy saving RO membrane, BW Brackish water desalination RO membrane, FR Fouling Resistant RO membrane, as well as XLE Extreme Low Pressure RO membrane, and High Salinity Brackish Water Desalination RO membrane.

 

Q2: What is Salt Rejection Ratio?

A2: The Salt rejection describes the quality of salt removed from the Reverse Osmosis feed water stream as a percentage. It's one of the key element of the RO membrane quality, however, other essential elements such as RO membrane performance durability, stability, application scope in different region, and permeate flow output at the same pressure will all be the important factors to judge the quality of the membrane.

 

Q3: Is the Salt reation of the RO membrane the higher the better?

A3: This will be depending on the feed water quality, if the feed water quality is good, even a 90% salt rejection membrane will be workable, if the feed water is with bad quality and with brackish water environment, a higher salt rejection above 95% is an ideal choice. For any membrane that meet the local drinking water standard will be a good membrane.

 

Q4: Is there are any other element we need to take into consideration when selection the RO membrane?

A4: Yes, the pre-treatment filter cartridge and pre-treatment system will affect the RO membrane performance as well, please select good quality filters and pre-treatment system.

 

Q5: Why there are white foam-like water being in the treated water at the initial usage?

A5: To preserve the RO membrane for a long shelf-life, and prevent the membrane from being oxydized, a water soluble protection material is coated on the surface of the membrane, which will be rejected in both the rejected water and treated water, for initial use, both rejected water and treated water should be rejected and the the RO membrane should be thourghly cleansed. The treated water at initial use shall not be injected to the water storage tank.

 

Q6: Why there are bublles in the treated water?

A6: Oxygen and Nitrogensand carbon dioxide is water soluble in the molecular form, during the water filtration process in the Reverse Osmosis process, those air will be released due to the pressure change between input water and output water. Those air is not harmful, just like Coca-cola.

 

Q7: Why dry RO membrane has a salt rejection rising process from its initial usage?

A7: The performance of the RO membrane is strictly conencted to the wetness of the membrane, when the membrane is wet, it will reach to ts maximum performance, dry membrane has a process to become wet from its initial usage. Make sure that the membrane hsould be rinsed after each usage.

 

Q8: Why Active carbon filter is requested for RO membrane?

A8: Chloride and chlorine content is harmful from the feed water, RO membrane is easily to be damaged as the surface of the RO membrane will be easily being oxydized.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier